SUPERSERVER 1028TR-T/TF User's Manual
3-2
3-3 Control Panel LEDs
There are fi ve LEDs that provide status information about the system.
NIC2: Indicates network activity on GLAN2 when fl ashing.
Information LED
See the following table for the status shown by this LED.
Information LED
Status Description
Continously on and red An overheat ocondition has occured. (This may be caused by cable congestion.)
Blinking red (1 Hz) Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz) Power failure: check for an inoperative power supply.
Solid blue Local UID has been activated. Use this function to locate the server in a rack
environment.
Blinking blue (300 msec) Remote UID has been activated. Use this function to locate the server from a
remote location.
Power: The main power switch is used to apply or remove power from the power
supply to the server system. Turning off system power with this button removes the
main power but keeps standby power supplied to the system. Therefore, you must
unplug system before servicing.
Reset: The reset button is used to reboot the system.
3-2 Control Panel Buttons
The chassis includes two push-buttons that control power to the system.