47
Chapter 4: Motherboard Connections
Fan Fail and UID LED
Connect an LED cable to pins 7 and 8 of the front control panel to use the Overheat/Fan
Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. Refer
OH/Fan Fail Indicator
Status
State Denition
Off Normal
On Overheat
Flashing Fan Fail
OH/Fan Fail LED
Pin Denitions (JF1)
Pin# Denition
7 Blue LED
8 OH/Fan Fail LED
Power Fail LED
The Power Fail LED connection is located on pins 15 and 16 of JF1. Refer to the table below
Power LED
Pin Denitions (JF1)
Pins Denition
5 +3.3V
6 Power Fail LED
Reset Button
Pin Denitions (JF1)
Pins Denition
3 Reset
4 Ground
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins
11 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC
LED cables to NIC1 and NIC2 LED indicators to display network activities. Refer to the table
LAN1/LAN2 LED
Pin Denitions (JF1)
Pins Denition
9/11 +3.3V
10/12 NIC Activity LED