SUPERSERVER 5018A-TN7B User's Manual
3-2
3-3 Control Panel LEDs
Power: The main power switch is used to apply or remove power from the power
power but maintains standby power. To perform many maintenance tasks, you must
unplug system before servicing.
Reset: The reset button is used to reboot the system.
NIC2
Information LED: Alerts operator of several states, as noted in the table below.
Information LED
Status Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure, check for an inoperative fan.
Solid blue
UID has been activated locally to locate the server in a rack
environment.
Blinking blue
UID has been activated using IPMI to locate the server in a
rack environment.
3-2 Control Panel Buttons
The chassis includes two push-buttons that control power to the system.