44
X10SRM-F/-TF User Manual
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below
for pin denitions.
Power LED
Pin Denitions (JF1)
Pins Denition
15 3.3V
16 PWR LED
Power Button
1
NIC1 LED
Reset Button
2
HDD LED
Power LED
Reset
PWR
UID SW
Ground
Ground
19 20
NIC2 LED
P3V3_STB
P3V3_STB
X
X
NMI
Ground
UID LED
OH/Fan Fail LED
P3V3
P3V3 PWR Fail LED
1
3
2
NMI Button
The non-maskable interrupt (NMI) button header is located on pins 19 and 20 of JF1. Refer
to the table below for pin denitions.
NMI Button
Pin Denitions (JF1)
Pins Denition
19 Control
20 Ground
HDD LED
The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to pin 14 to
show hard drive activity status. Refer to the table below for pin denitions.
HDD LED
Pin Denitions (JF1)
Pins Denition
13 3.3V Stdby
14 HDD Active
1. HDD LED
2. PWR LED
3. NMI

Table of Contents