BIOS Codes
BIOS Error POST (Beep) Codes
During the POST (Power-On Self-Test) routines, which are performed upon each system
boot, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue to boot. These
error messages normally appear on the screen.
Fatal errors will not allow the system to continue with boot up. If a fatal error occurs, you
should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The table
below lists some common errors and their corresponding beep codes encountered by users.
BIOS Beep (POST) Codes
Beep Code Error Message Description
1 beep Refresh Circuits have been reset (Ready to power up)
5 short, 1 long Memory error No memory detected in system
5 long, 2 short Display memory read/write error Video adapter missing or with faulty memory
1 long continuous System OH System overheat condition