Chapter 4: AMI BIOS
4-25
MECI
The Multiple Event Count Increment (MECI) counter counts the number of oc-
curences a duplicate event must happen before the MECI counter is incremented.
This is a numeric value ranging from 1 to 255.
METW
The Multiple Event Time Window (METW) denes number of minutes must pass
between duplicate log events before MECI is incremented. This is in minutes, from
0 to 99.
View Smbios Event Log
This feature displays the contents of the SmBIOS Event Log.
View System Event Log
This feature displays the contents of the System Event Log.