INSTALLATION
SureCall Force-5 Cellphone-Mate, Inc. Page 8
All rights reserved.
IMPORTANT: A minimum separation distance of 30 vertical feet is necessary
between the outside and inside antennas. If the inside coverage is not sufficient, you
may need as much as 80 feet of separation. See the following table.
x Use directional flat-panel antennas for long, narrow spaces. Mount them
as close as possible to the center of the wall at one end of long narrow
space.
x Use omnidirectional dome antennas for square spaces favorable to using
a central antenna. Mount them in the ceiling, as close to the center of the
desired coverage area as possible, with the domed side pointing down
2. Using the CM400 cable, connect the inside antenna to the booster connector
marked INSIDE (see page 5).
3. Hand tighten the connection.
To Use This Much Booster Gain...
Allow This Much Separation...
40 dB
5 10 feet
45 dB
15 20 feet
50 dB
50 - 55 feet
55 dB
55 65 feet
65 dB
70 80 feet