130 VL1500K5 (’05-MODEL)
REGULATOR/RECTIFIER
• Remove the secondary gear case cover.
(!VL1500 Service Manual 3-7)
• Disconnect the couplers and remove the regulator/rectifier
1.
• Measure the voltage between the terminals using the multi
circuit tester as indicated in the table below. If the voltage is
not within the specified value, replace the regulator/rectifier
with a new one.
# 09900-25008: Multi-circuit tester set
/ Tester knob indication: Diode test (0)
B: Black, B/R: Black with Red, B/W: Black with White tracer
✽ 1.4 V and more (tester’s battery voltage)
NOTE:
If the tester reads 1.4 V and below when the tester probes are not connected, replace the battery of the
multi-circuit tester.
Unit: V
+ Probe of tester to:
-
Probe of tester to:
B/R B1 B2 B3 B/W
B/R
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2
B1 ✽✽✽
0.4 – 0.7
B2 ✽✽ ✽
0.4 – 0.7
B3 ✽✽✽
0.4 – 0.7
B/W ✽✽✽✽
B1
B2
B3
B/W
B/R
SAMPLE