VL1500K5 (’05-MODEL) 173
Connect the 12 V battery to the PAIR control solenoid valve
terminals and check the air flow.
If air does not flow out, the solenoid valve is in normal condi-
tion.
Check the resistance between the terminals of the PAIR con-
trol solenoid valve.
" Resistance: 20 – 24 at 20 – 30 °C (68 – 86 °F)
# 09900-25008: Multi-circuit tester set
) Tester knob indication: Resistance ()
If the resistance is not within the standard range, replace the
PAIR control solenoid valve with a new one.
Installation is in the reverse order of removal.
Connect the lead wire coupler of the PAIR control solenoid
valve and PAIR hoses securely.
PAIR system hose routing. (!Page 175)
SAMPLE