Pressure Warning and Alarm
When the pressure reduces to 10% (of the range) above the set
low-pressure alarm threshold, the cab pressure level display color will
change to amber.
When the pressure level reaches the set low-pressure alarm threshold, the
cab pressure level display will change color to red and the alarm will sound.
If the pressure increases to 10% (of the range) below the set high-pressure
alarm threshold, the cab pressure level display color will change to amber.
If the pressure level reaches the set high-pressure alarm threshold, the cab
pressure level display will change color to red and the alarm will sound.
The alarm condition will remain until the pressure returns to within the alarm
thresholds or the monitor is reset (cycled off/on).
The audible alarm can be muted. (See Muting the Alarm, page 14)
CO
2
Warning and Alarm
When the CO
2
level increases to 10% (of the range) below the set primary
CO
2
alarm threshold, the CO
2
PPM level display color will change to
amber.
If the CO
2
PPM level reaches the set primary CO
2
PPM alarm threshold,
the CO
2
PPM level display will change color to red and the alarm will
sound.
The alarm condition will remain until the CO
2
PPM level returns to within
the primary alarm threshold or the monitor is reset (cycled off/on).
The audible alarm generated by the primary set CO
2
PPM alarm threshold
can be muted. (See Muting the Alarm, page 14)
If the CO
2
PPM level reaches 2500 PPM, the secondary, non-adjustable
CO
2
PPM alarm will sound, and it is only able to be muted for a set interval
between 0-10 minutes until cab conditions return to within thresholds.
Filter Life Warning and Alarm
When the filter life hours decrease to 20% of the maximum filter life
hours remaining, the filter identification display will change color to
amber.
If the filter life hours reach the maximum filter life hours, the filter
identification display will change color to red and the alarm will sound.
The alarm condition will remain until the expired filter(s) is replaced.
(See Replacing the Filter, page 14)
The audible alarm can be muted. (See Muting the Alarm, page 14)
200
1000
1
000
20
CO
2
FEFF218
PF ISO 35 H
H13 HEPA
50
200
1000
1
000
20
CO
2
FEFF218
PF ISO 35 H
H13 HEPA
50
200
1000
1
000
20
CO
2
FEFF218
PF ISO 35 H
H13 HEPA
50210
Alarm Color Codes
Green: Below limit, up to 89% of
set primary CO2 threshold
Amber: 90% to 99% of set
primary CO
2
threshold
Red: At or above primary CO
2
threshold
Alarm Color Codes
Green: Inside of set permissible limits
Amber: 10% above set low-pressure
threshold or 10% below set
high-pressure threshold
Red: At or outside of the set low or
high threshold
Alarm Color Codes
Green: 21% to 100% of filter life remaining
Amber: 20% or less of filter life remaining
Red: No filter life remaining