OperationManual
Sy‐Klone.com/RAinfoJune2021
Replacing the Filter
• Replace filter(s) per standard operating procedure.
• Go to Filter Selection Screen, page 7, to remove and reassign the filter.
This will restore filter life to 100% and set filter-life hours to default maximum
value.
1. Set left Selected Filter Display to REMOVED.
2. Press filter housing number of filter that was replaced until
REMOVED and filter housing number show on the Installed Filter
Display.
3. Press Confirm button, then press Filter Selection Menu button
on Main Menu to reassign new filter.
4. Filter housing is now available to reassign filter type following the
steps on page 7.
• If you wish to change the filter-life hours after reassigning the filter, see the
Filter Life Setting screen, page 9.
Muting the Alarm
• During active alarm conditions, the Alarm button will change to the Silence
Alarm button.
• Press the Silence Alarm button to silence the audible alarm.
• The Silence Alarm button will remain until the alarm condition is resolved.
ENGLIT0000342D
14
SilenceAlarm
Button
Alarm
Button
Bluetooth Setting
If the background of the Pressure Display on the
main display is not showing Red, Amber, or Green,
the APS has not connected.
Reconnecting Instructions:
1. To restart, cycle power to the RESPA Advisor+.
2. If the APS does not connect after 30 sec, press
the Scan button to scan for available devices.
3. An APS should appear in the Scanned Devices
display. Press the Connect button.
4. Press the Up/Down Connected Devices
buttons. The APS should now show in the
Connected Devices display.
NOTE: If the RESPA Advisor+ still cannot be connected to
an Ambient Pressure Sensor (APS), contact Sy-Klone at
support@sy-klone.com.
Connected Devices
Scanned Devices
Disconnect a
connected
device
Select
connected
device
List of connected devices
Connect
selected
device
Select
available
device
Confirm
button
Cancel
button
Main menu
button
Info button
Home
button
Filter removed
REMOVED
FEFF218
PF ISO 35 H
H13 HEPA
12 345 6 7 8
2