54
PROGRAMMING
Menu Level 2: Steam Oset
Menu Level 2: Calibrate Flowmeters
The owmeter calibraon feature is made available with rmware v2.64.
The feature allows for technicians and advanced users to calibrate the owmeters in order to achieve ex-
treme accuracy in their output volumes or to recalibrate owmeters that have become less accurate over
me due to mineral buildup.
Line 3 allows the operator to begin the calibraon. Before performing the calibraon please read the in-
strucons on page 69. Instrucons should be carefully followed in order to ensure proper volumetric func-
oning of the machine.
To cycle to the next display screen, press the down buon.
Line 2 indicates the measured steam temperature at the steam tank temperature probe.
Line 3 is the oset used to calibrate the steam tank temperature and pressure so that when the steam tank is
set at 250°F, there is 1.3 bar pressure on the gauge.
Line 4 of this display screen is showing a 5 second delay. The ll probe will wait this long before turning the
steam tank ll valve on or o. Add me here if the machine is in an unstable installaon such as a food truck
or catering cart. There is no need to drop this me below 5 seconds.
Contact Synesso Technical Support if you need to obtain the original, factory-determined oset values.
To cycle to the next display screen, press the down buon.