TROUBLESHOOTING
• Debris caught in the ll valve or valve is worn. Inspect the valve.
• Debris caught in the inlet ow restrictor. Remove inlet tube and inspect threaded ow restrictor for clog.
• Level probes (lower and upper) are touching. Angle the probes away from each other.
• Electrical signal error. Contact Synesso™ Technical Support for further troubleshoong.
Steam Tank is Overlling:
• Water quality is not in spec. The water level probe requires a low level mineral content in order to detect
the water and relay informaon to the CPU. Do not use deionized water in the machine.
• Debris caught in the water control valve or worn out valve.
• Calcium deposits on the ll probe are prevenng the probe from detecng the water level.
The Sight Glass Shows Over or Under Filled Steam Tank:
• Machine is not level. Check to make sure the surface that holds the machine is level. Slightly adjust leg
height to level the machine.
• Water level is too high; use the hot water spout to drain water from the steam tank. Connue releasing
hot water unl the autoll system acvates. Once autoll stops, recheck the water level.
• Debris is stuck in the water control ll valve.
• Level probes require inspecon. Clean or replace probes as needed.
Steam Has Undesirable Smell; Water from Tank is Discolored and/or Has Debris:
• The tank is contaminated. Drain the tank and rell. If quality of water and steam does not improve, soak-
ing the tank with a cleaning or descaling soluon may be necessary along with more clean water rinses.
Please re-read best pracces regarding steam wand purging before and aer steaming (see page 24).
• Inspect the vacuum breaker. If vacuum breaker is stuck closed, replace.
Steam Valve
Steam Valve Stem Seal Leaks:
• Replace O-rings. Purchase Rebuild Kit
Steam Valve Stem is Engaged; No Steam or Weak Pressure:
• Inspect steam wand p. Make sure all holes are cleared.
• Disassemble valve and inspect for debris.
• Steam valve shuto valve is not in the fully ON posion
• Buildup in steam pathway. Inspect tubes and ngs for clog, can be caused by scale buildup in steam
outlet ng of steam tank.
Hot Water Tap
No Water Flows When the Switch is Pressed:
• One or more of the following components may have failed: the hot water switch, the solenoid switch, the