Laser Safety
Table 2-1 Class 4 safety features.
Required by: Available on:
Feature Location / Description CDRH EN60825-1 OEM Laser
Keyswitch
1
Rear panel control Yes Yes No
On/O/Reset Keyswitch controls power to laser electronics. Key cannot be removed
from switch in the “On position.
Shutter
1
Laser control Yes Yes Yes
function Functions as a beam attenuator to disable RF driver/laser output when closed.
Shutter Rear panel indicator (Blue) No No Yes
indicator Illuminates blue to indicate shutter is open.
Ready Rear panel indicator (Yellow) Yes Yes Yes
indicator Indicates that laser has power applied and is capable of lasing.
Lase Rear panel indicator (Red) Yes Yes Yes
indicator Indicates that is actively lasing. Lase LED illuminates when the duty cycle of the Com-
mand signal is long enough to produce laser output.
Five second circuit element Yes No Yes
delay Disables RF driver/laser output for ve seconds after Keyswitch is turned to “On or
remote reset/start pulse is applied when Keyswitch is in “On position.
Power fail circuit element Yes Yes No
lockout
1
Disables RF driver/laser output if input power is removed then later reapplied (AC
power failure or remote interlock actuation) while Keyswitch is in “On position.
Remote Rear panel connection Yes Yes Yes
Interlock Disables RF driver/laser output when a remote interlock switch on an equipment door
or panel is opened.
Remote Rear panel indicator (green/red) No No No
Interlock INT Illuminates green when Remote Interlock circuitry is closed. Illuminates red when
indicator interlock circuitry is open.
Over circuit element No No Yes
temperature Temperature shutdown occurs if temperature of the laser protection tube rises above
safe operating limits.
Temp Rear panel indicator (Green/Red) No No Yes
indicator Illuminates green when Remote Interlock circuitry is closed. Illuminates red when
interlock circuitry is open.
Warning laser exterior Yes Yes Yes
labels
Labels attached to various external housing locations to warn personnel of potential
laser hazards.
1 Not available on laser OEM lasers
SYNRAD
®
laser lasers have demonstrated performance characteristics that have met or ex-
ceeded the requirements of EMC Directive 2014/30/EU.