Software
SYS TEC electronic GmbH 2001 L-487e_6
27
•
RTR-Per.: period of time between the reception for the last two
remote frames
•
RTR-Cnt.: number of remote frames with this identifier
Transmit Section
The Transmit section provides the following information:
•
Message: identifier of the CAN message, hexadecimal format,
ranging from 0 to 7FFh for 11-bit identifiers and from
0 to 1FFFFFFFh fro 29-bit identifiers
•
Length: data length code of the message (ranges from 0 to 8)
•
Data: values of the messages’ data bytes (up to 8) or the text
Remote request, if a remote frame shall be sent
•
Period: period of time between the last two message sent
Note:
If, at creation of the message, the period was set to 0, the text Wait is
shown. In this case the message can only be transmitted manually
using the <Space> bar. Or the message is sent automatically after a
matching remote frame has been received.
•
Count: number of messages sent with this identifier (no
remote frames) since last user reset
•
Trigger: reason for the last transmission of the message
•
Manual: manual transmission by the user pressing the <Space>
bar
•
Time: period of time has passed for periodical sending
•
RTR: remote frame has been received
In order to edit the Transmit list, the following menu commands are
available:
•
Transmit | New...: Create a new transmit message. The editor
window for the new message is shown.
•
Transmit | Delete: Delete the currently selected message from

Table of Contents