EasyManua.ls Logo

Sys Tec Electronic USB-CANmodul - Page 29

Sys Tec Electronic USB-CANmodul
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Software
SYS TEC electronic GmbH 2001 L-487e_6
27
RTR-Per.: period of time between the reception for the last two
remote frames
RTR-Cnt.: number of remote frames with this identifier
Transmit Section
The Transmit section provides the following information:
Message: identifier of the CAN message, hexadecimal format,
ranging from 0 to 7FFh for 11-bit identifiers and from
0 to 1FFFFFFFh fro 29-bit identifiers
Length: data length code of the message (ranges from 0 to 8)
Data: values of the messages’ data bytes (up to 8) or the text
Remote request, if a remote frame shall be sent
Period: period of time between the last two message sent
Note:
If, at creation of the message, the period was set to 0, the text Wait is
shown. In this case the message can only be transmitted manually
using the <Space> bar. Or the message is sent automatically after a
matching remote frame has been received.
Count: number of messages sent with this identifier (no
remote frames) since last user reset
Trigger: reason for the last transmission of the message
Manual: manual transmission by the user pressing the <Space>
bar
Time: period of time has passed for periodical sending
RTR: remote frame has been received
In order to edit the Transmit list, the following menu commands are
available:
Transmit | New...: Create a new transmit message. The editor
window for the new message is shown.
Transmit | Delete: Delete the currently selected message from

Table of Contents