MenuLevel1MenuLevel2MenuLevel3Explanation
Functions
Digitaloutput
Digitaloutput
1:SF67%
2:EF67%
3:RotON/OFF
4:ALARMY/N
5:DmpY/N
6:ReheaterY/N
ShowsThecurrentsettings
ofdigitaloutputs1–6(the
settingsinthecolumntothe
leftareexamples).
1:SF67%:Currentsetspeed
ofthesupplyairfan(shownas
percentageofthemaximum
speed).
2:EF67%Currentsetspeed
oftheextractairfan(shownas
percentageofthemaximum
speed).
3:Showsiftherotorisactive
ornot.
4:AlarmY/N:Indicatesifthe
sum.alarmisactiveornot
5:DmpOFF:Outdoor/exhaust
airdamperisonoroff.
6:ReheaterY/N:Indicates
iftheelectricalre-heateris
activeornot.
Functions
Defrosting
Defrosting
Mode0–5
Usethisdialogueframetoset
howaggressiveyouwantthe
defrostingfunctiontooperate
(seechapter6.5).
Functions
Modbus
Modbus
Address1
Baud9600/19200
ParityNone/Even/Odd
InformationaboutModbus
communicationandvariables
canbefoundintheModbus
usermanualforresidential
unitsintheonlinecatalogueat
www.systemair.com.
Functions
Factoryreset
Factoryreset
Reallyreset?YES/NO
Usethisdialogueframeto
returntofactorysettings.
SetYESorNO
Note:
Thiswilleraseallyour
personalsettingsthathave
beendonefortheunit.
Service
Language
Languages
Language
ENGLISH
Usethisdialogueframeto
returntoselectyourlocal
language.
SetLanguagebyturningthe
SELECTIONknob.
SAVEVTR300/BInstallationandService
208348
31