TM8100/TM8200 Service Manual Transmitter Fault Finding (40W/50W) 273
© Tait Electronics Limited June 2006
Task 6 —
Power Unchanged
Regardless of
Setting
If all the power and current values measured in Task 5 are correct, it is likely
that the power remains unchanged regardless of the power setting.
1. Enter the following CCTM commands in turn and measure the RF
output power in each case:
â– 326 4
â– 326 3
â– 326 2
â– 326 1
2. The above measurements should confirm that the power remains
unchanged at all settings. Carry out Tas k 1 2
and then Ta s k 19 .