EasyManuals Logo

Tait TP9300 User Manual

Tait TP9300
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16 For your safety
Entity parameters
The Entity Concept allows interconnection of IS/NI
equipment with associated equipment when the following
is true:
Ui
Uo, Ii
Io, Pi
Po, Ci
Co, Li
Lo, and Li/Ri
Lo/Ro.
The installation must be in accordance with the following
standards:
National Electrical Code (NEC), ANSI/NFPA 70, Arti-
cles 504 and 505
Canadian Electrical Code (CEC) Part I, CAS C22.1
ANSI/ISA-RP12.06.01
EN/IEC 60079-25
relevant local regulations.
TP9300/TP9400 IS/NI radios have the following entity
parameters.
Radio accessory port:
Radio battery port:
Uo 7.2 V
Io 0.42 A
Po 1.3 W
Co 1.97
μ
F
Lo 100
μ
H
Lo/Ro 20
μ
H/
Ω
Ui 8.4 V
Ii IIA: 2.9 A
IIC: 1.9 A
Um 9.0 V (charging)
Ci 1.2
μ
F
Li 5.7
μ
H

Table of Contents

Other manuals for Tait TP9300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tait TP9300 and is the answer not in the manual?

Tait TP9300 Specifications

General IconGeneral
IP RatingIP67
Frequency BandsVHF: 136-174 MHz, UHF: 400-470 MHz
Power OutputVHF: 5W; UHF: 4W
Battery LifeUp to 14 hours
Channel Spacing12.5 / 25 kHz
Operating Voltage7.4V
Battery Capacity2000 mAh
Digital ProtocolDMR Tier II
RF Output PowerVHF: 5W; UHF: 4W
Operating Temperature-30°C to +60°C
EncryptionAES-256
GPSYes
DisplayHigh-resolution LCD