Installation
11Page
DO NOT adjust any dipswitches on the right bank for the 510 (T-D2) models.
The dark squares indicate the direction the dipswitches should be set to.
Dipswitches
HIGH-ALTITUDE INSTALLATIONS
Check the elevation where your water heater is installed. Set dipswitches shown in the table below
depending on the altitude.
Altitude
0 to 2,000 ft
(DEFAULT)
2,000 to 4,000 ft
4,000 to 6,000 ft
Over 6,000 ft
Switch No.3
OFF
ON
OFF
Consult
our Technical
Services
Department
at 1-877-
737-2840
Switch No.4
OFF
OFF
ON
Altitude
0 to 2,0
00 ft
(DEFAULT)
2,000 to 4,000 ft
4,000 to 6,000 ft
Over 6,000 ft
Switch No.4
OFF
ON
OFF
Consult
our Technical
Services
Department
at 1-877-
737-2840
Switch No.5
OFF
OFF
ON
110 (T-KJr2) and 310 (T-K4) models
510 (T
-
D2) models (Left bank of dipswitches)
110 (T
-
KJr2) and 310 (T
-
K4) models
Computer board
WARNING
510 (T
-
D2) models Co
mputer board
Left bank of dipswitches
OFF
ON
1 2
3 4
5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6
O
FF
ON
1
2 3 4 5 6
OFF
ON
1
2
3
4
5
6