97
MAINTENANCE
Service Data
Expendables
Replace expendables such as filters and elements periodically, referring to the table below.
Replace the hydraulic oil regularly!
Replacement Interval (Hours)
Item
Hydraulic Oil Return Filter
1st time 25
2nd time 100
Periodically 600 200
When the breaker operating ratio is 100%
Refer to page 174 “Hydraulic Breaker”.
¡When using a hydraulic breaker, the oil
deteriorates quicker than during normal
digging. Be sure to replace the hydraulic
oil and return filter element.
Failure to replace these in time can lead to
damage to the machine and breaker’s
hydraulic systems. In order to improve the
service life of the hydraulic systems, be
sure to replace the hydraulic oil and return
filter element according to the following
chart of the replacement interval.
Clean the suction strainer when
changing the return filter element.
Item Part name Part No.
Replacement interval
Return filter Element After first 50 hrs.
Every 500 hrs.
15511-01910
Fuel filter Every 500 hrs.Element 119802-55800
After first 50 hrs.
Every 250 hrs.
129150-35152
Engine oil filter
Cartridge
Every 1000 hrs. or
after 6 cleanings
(whichever comes
first)
Air cleaner Element
(outer)
119808-12520
Every 1000 hrs. or
after 3 cleanings of
the outer element
(whichever comes
first)
Inner Element
(option)
19111-02772
Air breather filter Every 1000 hrs.Element 15520-00902

Table of Contents

Other manuals for Takeuchi TB53FR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takeuchi TB53FR and is the answer not in the manual?

Takeuchi TB53FR Specifications

General IconGeneral
BrandTakeuchi
ModelTB53FR
CategoryCompact Excavator
LanguageEnglish

Related product manuals