4
Introduction
Models 104 & 220
104 Specifications
Freezing Cylinder
One, 3 quart (2.9 liter). Pre--charge of liquid mix
depends on desired overrun.
Beater Motor
One, 1.0 HP
Refrigeration Unit
One, approximately 2,500 BTU/hr. R404A
(BTU’ s may vary depending on compressor used.)
Electrical
Electrical
One dedicated connection
Maximum
Fuse Size
Minimum
Circuit Ampacity
115/60/1 Air 35 29
208-230/60/1 Air 15 15
220-240/50/1 Air 15 12
This unit is also available with other electrical
characteristics. (For exact electrical information,
always refer to the data label of the unit.)
Air Cooled
Clearance: 6” (152 mm) around all sides.
Dimensions
Width: 16--7/16” (418 mm)
Depth: 26--13/16 (681 mm)
Height:21--3/8” (542 mm)
Counter Clearance: Unit is designed to rest on a
plastic pad directly on the counter top.
Approximate Weights
Net: 165 lbs. (74.8 kgs.)
Crated:204 lbs. (92.5 kgs.)
This unit is designed and constructed to meet stringent
safety and sanitation requirements for NSF and other
food service regulatory agencies.