16
Model 220Operating Procedures
Figure 25
Step 5
Place the control switch in the “EJECT” position. This
will cause the sanitizing solution in the freezing
cylinder to be agitated. Allow to agitate for five
minutes.
Figure 26
Step 6
Place the control switch in the “OFF” position.
With an empty mix pail beneath the ejection port, turn
the draw rod handle and pull forward, opening the
ejection port. Draw off all the sanitizing solution. When
the sanitizer stops flowing from the ejection port, push
the draw rod back into the valve body and lock into
place.
Figure 27
Step 7
Assemble the hopper gasket around the top edge of
the mix hopper.
Figure 28