OPERATING PROCEDURES
6-5
Models 441 & 444
Operating Procedures
6
Figure 6-15
6. When the sanitizer stops flowing from the door spout,
lower
the draw arm and place the control switch in
the OFF position.
Important! T
he unit must NOT be placed in AUTO
until all sanitizing solution has been removed from
the freezing cylinder and proper priming procedures
have been completed. Failure to follow this
instruction may result in damage to the freezing
cylinder.
IMPORTANT! If this
machine is freshly
sanitized, make sure your hands are sanitized before
con
tinuing these instructions. Failure to follow this
instruction may result in health hazards.
7. Stand the mix feed tube in
the corner of the mix
hopper.
Figure 6-16
Repeat steps 1 through 7 for the other side of the
freezer on the Model 444.
Priming
Prime the machine as closely to the time of first product
draw as possible.
1. Place a pail beneath the door spout and raise the
dr
aw arm. Pour 2 gal (7.6 L) of fresh mix into the
hopper and allow it to flow down into the freezing
cylinder. This will force out any remaining sanitizing
solution.
Figure 6-17
2. When full strength mix is flowing from the door spout,
lo
wer the draw arm.
Important! Failure to remove
all sanitizing solution
may result in damage to the freezing cylinder.
3. When the mix has stopped bubbling down into the
fr
eezing cylinder, install the mix feed tube into the mix
inlet hole.
Figure 6-18