34
Models 60 & 62Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
12. Water continues to flow
through spinner housing.
a. Rinse solenoid stuck
open.
a. Call service technician for
repair .
---
13. Lift motor continues to
raise draw valve after
draw of product has been
made.
a. Micro switch needs
adjustment.
a. Call service technician for
repair .
---
14. Air compressor runs too
often for normal usage.
a. Air leak in system. a. Use a soap solution to
locate the leak.
---
15. Spinner shaft will not
rotate to blend syrup into
product.
a. Flexible cable broken. a. Call service technician to
replace cable.
---
b. Pin missing in female
quick disconnect.
b. Call service technician to
replace disconnect.
---
c. Spinner motor out on
thermal overload.
c. Inadequate lubrication of
spinner shaft. Lubricate
entire length of shaft.
16
16. Excessive drippage of
product from spinner
housing.
a. Worn o- rings on draw
valve.
a. Replace every 3 months. 35
b. Wrong o- rings on draw
valve.
b. Check o- ring size. ---
c. Inadequate lubrication of
spinner shaft.
c. Follow lubrication
procedures in “Assembly”.
16