21
Model C723
Controls, Systems and Operations
The FAULT HISTORY screen displays a history of
the last 100 faults. Page numbers are displayed in
the upper right-hand corner. Page 1 contains the
most recent fault. Use the arrow keys to cycle
through the history pages. The date and time of the
event are displayed on the second line. The third
line displays the reason for the fault.
(See Figure 30.)
FAULT HISTORY 1
02/27/11 12:58
HPCO COMPRESSOR
> Exit
Figure 30
The LOCKOUT HISTORY screen displays a history
of the last 100 hardlocks, brush clean dates, etc.
(See Figure 31.)
LOCKOUT HISTORY
02/27/11 12:58
< HPR THERM FAIL
> Exit
Figure 31
Use the arrow keys to advance forward or backward
to view each screen. The following list indicates the
variable messages that may appear. Press the SEL
key to return to the Manager's Menu.
Faults Occurring While in AUTO or
Standby Mode
L - R HPR Therm Fail - The hopper thermistor
failed. Call for service.
L - R BRL Therm Fail - The freezing cylinder
thermistor failed. Call for service.
L - R HPR>59F (15C) - The mix temperature in the
hopper exceeded 59_F (15_C).
L - R BRL>59F (15C) - The mix temperature in the
freezing cylinder exceeded 59_F (15_C).
L - R HPR>45F (7C) AFTER 1 HR - The mix
temperature in the hopper was above 45_F (7_C)
more than one hour.
L - R BRL>45F (7C) AFTER 1 HR - The mix
temperature in the freezing cylinder was above 45_F
(7_C) more than one hour.
L - R HPR>41F (5C) AFTER 4 HR - The mix
temperature in the hopper was above 41_F (5_C)
more than four hours.
L - R BRL>41F (5C) AFTER 4 HR - The mix
temperature in the freezing cylinder was above 41_F
(5_C) more than four hours.
L - R HPR>41F (5C) AFTER PF - The mix
temperature in the hopper was above 41_F (5_C)
more than four hours following a power failure.
L - R BRL>41F (5C) AFTER PF - The mix
temperature in the freezing cylinder was above 41_F
(5_C) more than four hours following a power failure.
Note: Refer to your local health codes regarding
temperature recommendations for procedures to
follow if these fault screens appear.

Other manuals for Taylor C723

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C723 and is the answer not in the manual?

Taylor C723 Specifications

General IconGeneral
TypeSoft Serve Freezer
Mix FlowGravity
Number of Flavors2 + Twist
Electrical208-230/60/1
Freezing Cylinder Size3.4 qt (3.2 L)

Related product manuals