8-2
TROUBLESHOOTING GUIDE
087482-M
Troubleshooting Guide
8
8. Product is not feeding
into the freezing
cylinder.
a. The mix level is inadequate in the
mix hopper.
a. Fill the mix hopper with mix.
5-3
b. The air orifice is not installed. b. Install the air orifice in the air tube.
6-8
c. The air tube is installed incorrectly. c. Install the air tube in the mix inlet
hole, using the end with the small
hole in the side.
6-8
d. The mix inlet hole is frozen. d. Contact service technician.
---
9. The unit goes out on
overload excessively.
a. There are too many appliances
plugged into the circuit.
a. A separate 20 A circuit is needed for
the freezer to operate properly.
---
b. An extension cord has been placed
between the power cord and the
wall receptacle.
b. If the extension cord is used, it must
match the power cord in size of circuit
ampacity.
---
10. Mix from one freezing
cylinder bleeds over to
the second cylinder.
a. The center draw valve seal is worn
or improperly lubricated.
a. Lubricate properly and replace seal
every 3 months.
6-1, 9-1