Energier Apollo User Manual
36
Items
Work mode
Battery type
Battery capacity
Select battery type to
configure suitable charging curve
Set actual battery capacity
to choose suitable maximum
charging current
AC source
Under voltage
alarm
AC input
current limit
To ensure the best compatibility
with AC input source
Standard, Weak-grid,
Generator, Weak-generator
To configure maximum AC input
current, details as chapter 2.4
To configure battery
under voltage alarm threshold
1A
~
32A 32A
24V:20.0~32.0VDC
48V: 40.0
~
64.0VDC
Lead acid 21.6VDC
LFP:24.8VDC
Lead acid 43.2VDC
LFP:46.5VDC
Descriptions
To configure load power source
priority, details as chapter 5.2
Power backup,
Solar mode
AGM, GEL, traction,
semi-traction, flooded, LFP,
lead-carbon
AGM
50AH
Power backup
Standard
Selectable options Default setting
50
~
3000AH
Under voltage
protection
To configure battery low
voltage disconnect threshold
24V:20.0~25.6VDC
48V: 40.0
~
51.2VDC
Lead acid 21.0VDC
LFP:23.2VDC
Lead acid 42.0VDC
LFP:44.0VDC
To configure power saving
mode threshold
0.5%
~
1% rated power 0.5%
To activate power save function Enable, disable Disable
Power save
Date & Time
To set date and time mm/dd/yyyy, hh:mm:ss
6.2 Default setting
The setting sub-menu include “General” and “Advanced” items.
General setting items descript as following table:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TBB Energier Apollo CH3.0S and is the answer not in the manual?

TBB Energier Apollo CH3.0S Specifications

General IconGeneral
BrandTBB
ModelEnergier Apollo CH3.0S
CategoryInverter
LanguageEnglish

Related product manuals