Energier Apollo User Manual
12
When Energier Apollo is set to “Power Backup Mode”, it will power AC load with grid or generator
as first priority in case AC input is present. When the AC input is not present, it will switch to inverter
mode automatically, then AC loads will be powered by solar and battery.
Power backup mode
Energier Apollo can be set to power backup mode or solar mode.
2.5 Working principle
When Energier Apollo is set to “Solar Mode”, solar energy provides power to the AC loads as first
priority. If solar energy is not sufficient to power all connected AC loads, battery will supply power
to the load at same time. Grid provides power to the AC loads only when battery voltage drops to
“inverter to grid” threshold. At that situation Energier Apollo will be back to invert mode when battery
voltage increases to “grid to inverter” threshold .Both threshold values are preset in the configuration.
Please refer 6.3.2 for details.
Solar mode
Notice: AC charger function should not be disabled in any working mode, when user
wants to charge the battery from grid or generator.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TBB Energier Apollo CH3.0S and is the answer not in the manual?

TBB Energier Apollo CH3.0S Specifications

General IconGeneral
BrandTBB
ModelEnergier Apollo CH3.0S
CategoryInverter
LanguageEnglish

Related product manuals