Energier Apollo User Manual
11
Weak Grid / generator mode settable
Weak grid / Generator mode will reduce its requirements for AC input (voltage, frequency and
waveform) and pass over the grid to power the load and meantime perform the charging. With this
setting, Energier Apollo can work with majority of generator in the market.
AGS (Automatic Generator Start) function
When programmable relay is set as AGS, it can be used to start and stop a generator automatically.
The start and stop condition can be battery voltage, battery charging phase, generator running time
or load capacity.With software Rapconfig supplied you can program this function.
RS485 communication
RS485/modbus is offered in Energier Apollo. It can be connected to the computer through
running the configuration software.
Complete system protection
Energier Apollo is being protected against many failures through hardware and software including
overload protection, overheat protection, short circuit, battery over temperature protection, battery
Low voltage etc.
Software programmable
Energier Apollo is fully programmed through PC with Rapconfig (through connection of RS485-USB
converter), of which you can obtain from TBB.
After installation, you need to do some basic configurations, of which can be done either on LCD
interface setting or through Rapconfig software of which you can obtain from TBB. The latest
configuration will be saved in Energier Apollo, no matter through which device.
If you perform the latest configuration through Rapconfig software or LCD interface setting, the
setting will be saved in Energier Apollo, please always use Rapconfig software or LCD interface to
read the latest configuration.