46
TECHNICAL SPECIFICATION
Model
iQool-C3MS9K9K9K
iQool-C2MS12K12K
Rated voltage and frequency (Ph-V-Hz)
1Ph/220-240V~/50Hz
1Ph/220-240V~/50Hz
Fuse Required
13A
13A
Mode
Cooling
Heating
Cooling
Heating
Rated capacity (W)
Single
2637
2637
3517
3517
Double / Triple
8200
(3100~8790)
9050
(2550~9800)
6150
(2800~6600)
6600
(2450~6900)
Power input (W)
Single
816
730
1083
970
Double / Triple
2500
(410~2700)
2200
(510~2850)
1880
(350~2100)
1710
(420~2050)
Current input (A)
Single
3.83
4.42
5.07
4.55
Double / Triple
11.3
(1.86~12.3)
9.8
(2.32~12.4)
8.5
(1.6~9.5)
7.8
(1.9~9.3)
SEER/SCOP(W/W)
6.1/A++
4.0/A+
6.1/A++
4.0/A+
Nominal load (kW)
8.20
9.05
6.15
6.60
Balance point temperature heating (
o
C)
/
-7
/
-7
Min. outdoor operating temperature (
o
C)
/
-15
/
-15
Thermostat-off mode (W)
161
129
Standby mode (W)
6
4
Off mode (W)
0
0
Annual consumption (kW)
470
2733
352
2098
Number of indoor units supplied
2
3
Max number of indoor units
3
4
Copper Pipe Type length
5m
5m
Liquid side / Gas side (mm/inch)
6.35 (1/4) + 9.52 (3/8)
6.35 (1/4) + 9.52 (3/8)
Max. refrigerant pipe length for each unit
15m
15m
Max. elevation
10m
10m
Interconnecting Cable
4×0.75mm²
4×0.75mm²
Fuse Rating
5A on indoor PCB
5A on indoor PCB
Moisture Removal (L/h)
0.9 L/h per one unit
0.9 L/h per one unit
Indoor
Air Flow (m
3
/h)
500
600
Dimensions (L*W*H) (mm)
574×574×250
574×574×250
Packaging (L*W*H (mm)
725×725×330
725×725×330
Net / Gross weight (Kg)
20/24
20/24
Noise Sound pressure level
(MPa)
36~42
36~42
Noise Sound power level
(dB/A)
46~52
46~52

Related product manuals