114-94438 REV C1
21 of 36
Step 5b
DC-HV-Cables of 50mm² in combination with CABLE EXIT AC 90° SIDEWARDS.
THE SINGLE BRAIDS MAY NOT BE CUT OR DAMAGED DURING DISMANTLE PROCESS.
Remove outer isolation and shielding-foil of DC-HV-Cable acc. dimension B (figure27).
Remove inner isolation acc. dimension A (figure 27).
Wire Size
Removal of isolation
"A"
Removal of outer
insulation
“B”
Position outer end
of COVER [POS.10]
“C”
50mm²
23 +/-0,5 mm
29 +/-0,5 mm
50 mm REF
Table 9
Take care, to protect single conductors and braid against contamination, bending and other damages
until crimping process.
The COVER CABLE SEAL DC [Pos. 10] and FAMILY SEAL DC [Pos. 11] must be pushed over the
DC-HV-wires (figure28)
Figure 27
Figure 28