3.2 Electrical connections
1. There is a ground contact on the left side of the housing to connect a ground wire. A crosshead (Phillips)
screwdriver should be used to tighten the ground screw to a torque value of 0.37 ft*lb (0.5 N*m).
Grounding screw located
on the side of the housing.
2. To install the coaxial cable, cut the connector pins to a length of 1.1" (28 mm) for threaded connectors
as shown below. When using 5/8"-18 UNC threaded connectors and 5/8" reducing rings, add 7/64" (2.5 mm)
to the connector pin length = 1.2" (30.5 mm).
3. Tighten the connectors into the housing in accordance with the connector manufacturer’s specification. The maximum
torque force for the coaxial connector and 5/8" adapter ring is 14.75 ft*lb (20 N*m).