EasyManua.ls Logo

Technomark M4 inline - Mechanical Function Setup

Technomark M4 inline
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 24 sur 26
TRAÇABILITÉ CRÉATIVE
CREATIVE TRACEABILITY
www.technomark-marking.com
Modèle du 06/11/2015
TECHNOMARK
3 Allée Michaël FARADAY
Parc d’activités STELYTEC
42400 SAINT-CHAMOND (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : info@technomark-marking.com
Error code
1st level
troubleshooting
Remedial action
Error codes 43, 44, 45, 46: USB
stick errors.
The USB stick used is defective.
Internal controller issue.
Try with another USB stick.
Restart the controller.
Contact the After-Sales
Customer Service Team.
Error code 49: Window error.
A marking point is outside the
window.
Check that there is no flag
indicating marking outside of
the window in the marking
overview. Reposition the text.
If the problem persists, contact
the After-Sales Customer
Service Team.
Error 50: Temperature error.
The machine has been in ‘test
position’ for too long and the
motors have been powered up
for too long.
The ambient temperature is
outside the usage ranges.
Successive marking of a
number of files with a large
number of characters and using
a tight matrix.
Turn the controller off for
around ten minutes and
restart.
Turn the controller off for
around ten minutes and
restart.
If the problem persists, contact
the After-Sales Customer
Service Team.
Reduce the number of impacts
by using another font.
Reduce the marking speed.
Reduce the marking force.
If the problem persists, contact
the After-Sales Customer
Service Team.
Error code 51: Marking busy.
The requested task cannot be
launched because the machine
is already busy.
Wait for the current task to end
or stop it.
Error 57: TechnoMATRIX
licence error.
The necessary licence is not
present in the controller.
Contact the After-Sales
Customer Service Team.

Other manuals for Technomark M4 inline