TECNA WELD TESTER TE1700
6.1.2 DATA SPOT PRINT
If the function is active, all the measurements performed will be
printed on the terminal, in green or red if the measurement is inside or
outside limits, and in black if the limits check is not active.
SPOT: 02864 07-11-2013 16:09:17
LIMIT MASK NUMBER: 01 LIMIT MASK EVAL RESULT: LIMIT OK
WELDING TIME: 003.0 CYCLES CONDUCTION DEG: 118
RMS CURRENT: 0004.70 kA
POSITIVE PEAK: 0007.58 kA NEGATIVE PEAK: 0008.25 kA
SECONDARY RMS VOLTAGE: 00.27V
SECONDARY POSITIVE PEAK: 00.46V SECONDARY NEGATIVE PEAK: 00.48V
ENERGY: 00071 J POWER MEAN: 001.26kW
SPOT: 02865 07-11-2013 16:09:50
LIMIT MASK NUMBER: 01 LIMIT MASK EVAL RESULT: NO LIMIT ACTIVE
WELDING TIME: 003.0 CYCLES CONDUCTION DEG: 118
RMS CURRENT: 0004.72 kA
POSITIVE PEAK: 0007.49 kA NEGATIVE PEAK: 0008.23 kA
SECONDARY RMS VOLTAGE: 00.27V
SECONDARY POSITIVE PEAK: 00.46V SECONDARY NEGATIVE PEAK: 00.48V
ENERGY: 00070 J POWER MEAN: 001.27kW