TECNA WELD TESTER TE1700
2 FORCE CONFIG MENU: For setting the force rate LOW, MID or
HIGH (i.e. 240 daN, 480 daN or 1,200 daN).
3 PRE BLANK CONFIG: For setting the PRE BLANK time in
milliseconds. Between 0 and 200 ms.
4 POST BLANK CONFIG: For setting the POST BLANK time in
milliseconds. Between 0 and 200 ms.
5 PULSE NUMBER CONFIG: For setting the number of pulses.
Between 1 and 9.
6 FORCE FILTER: Activates\Deactivates the filter on the force
measurement signal.
7 TRIGGER LEVEL: For setting the trigger level on the signal.
8 CONTINUOUS MODE: For selecting the type of signal acquisition
NORMAL\CONTINUOUS.
L LIMIT CONFIG: For accessing the submenu for setting
measurement check limits.