18
Group 04: External Analog Input and
Output Parameters
Code
Parameter
Name
Setting Range
Default
Attrib
ute
04-03 AI1 Bias -100.0~100.0 0 *1
04-04 Negative AI
0: Disable
0 Note4
1: Enable
04-05
AI2 Function
Setting
0: Auxiliary
Frequenc
0
1: Frequency
Reference Gain
2: Frequency
Reference Bias
3: Output
oltage Bias
4: Coefficient of
cceleration and
Deceleration
Reduction
5: DC Braking
Current
6: Over-Torque
Detection Level
7: Stall
Prevention Level
During Running
8: Frequency
Lower Limi
9: Jump
Frequency 4
10: Added to AI1
11: Positive
torque limi
12: Negative
torque limi
13: Regenerative
Torque Limi
14: Positive /
Negative Torque
Limit
15: Torque
Reference/
Torque Limit (in
Speed Control)
16: Torque
Compensation
17: PTC
Overheat
Protection
04-06
AI2 Signal
Scanning and
Filtering Time
0.00~2.00 0.03
04-07
AI2 Gain
0.0~1000.0 100.0 *1
04-08
AI2 Bias
-100.0~100.0 0 *1
04-09
~
04-10
Reserved
04-11
AO1 Function
Setting
0: Output
Frequency
0
1: Frequency
Command
Group 04: External Analog Input and
Output Parameters
Code
Parameter
Name
Setting Range
Default
Attrib
ute
2: Output
Voltage
3: DC Voltage
4: Output
Current
5: Output Power
6: Motor Speed
7: Output Power
Factor
8: AI1 Input
9: AI2 Input
10: Torque
Command
11: q-axis
Current
12: d-axis
Current
13: Speed
Deviation
14: Reserved
15: ASR Output
16: Reserved
17: q-axis
Voltage
18: d-axis
Voltage
19~20: Reserved
21: PID Input
22: PID Output
23: PID Target
Value
24: PID
Feedback Value
25: Output
Frequency of the
Soft Starter
26: PG Feedback
27: Reserved
28: Communication
control
04-12 AO1 Gain 0.0~1000.0 100.0 *1
04-13 AO1 Bias -100.0~100.0 0 *1
04-14
Reserved
04-15
04-16
AO2 Function
Setting
Range and
definition are the
same as those of
04-11.
3
04-17 AO2 Gain 0.0~1000.0 100.0 *1
04-18 AO2 Bias -100.0~100.0 0 *1
04-19
AO2 Output
Signal Type
0: AO2 0~10V
0
1: AO2 4~20mA
04-20
Filter Time of
AO Signal
Scan
0.00~0.50 0.00 *1