EasyManua.ls Logo

TECO F510 series - Page 25

TECO F510 series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Group 07: Start /Stop Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Time of PM
Speed
Search
07-45
STP2
Function
Selection
0:STP2 Enable
0
Note6
1:STP2 Disable
Group 08 Protection Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
08-00
Stall
Prevention
Function
xxx0b: Stall
prevention is
enabled in
acceleration
0000b
xxx1b: Stall
prevention is
disabled in
acceleration
xx0xb: Stall
prevention is
enabled in
deceleration
xx1xb: Stall
prevention is
disabled in
deceleration
x0xxb: Stall
prevention
is enabled
in operation
x1xxb: Stall
prevention
is disabled
in operation
0xxxb: Stall
prevention
in operation
decelerates
based on
deceleration
time 1
1xxxb: Stall
prevention
in operation
decelerates
based on
deceleration
time 2
08-01
Stall
Prevention
Level in
Acceleration
20~200 120
08-02
Stall
Prevention
Level in
Deceleratio
n
200V: 330~410 385
400V: 660~820 770
Group 08 Protection Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
08-03
Stall
Prevention
Level in
Operation
30~200 120
08-04 Reserved
08-05
Selection for
Motor
Overload
Protection
(OL1)
x
xx0b: Motor
Overload
Protection is
disabled
0001b
xxx1b: Motor
Overload
Protection is
enabled
x
x0xb: Cold
Start of Motor
Overload
xx1xb: Hot
Start of Motor
Overload
x0xxb:
Standard Motor
x1xxb: Special
motor
0xxxb:
Reserved
1xxxb:
Reserved
08-06
Start-up
Mode of
Overload
Protection
Operation
(OL1)
0: Stop Output
after Overload
Protection
0
1: Continuous
Operation after
Overload
Protection.
08-07
Motor
Overload
(OL1)
Protection
Level
0: Motor
overload (OL1)
Protection 0
0
Note3
1: Motor
overload (OL1)
Protection 1
2: Motor
overload (OL1)
Protection 2
08-08
Automatic
Voltage
Regulation
(AVR)
0: Enable
0
1: Disable
08-09
Selection of
Input Phase
Loss
Protection
0: Disable
0
1: Enable
08-10
Selection of
Output
Phase Loss
Protection
0: Disable
0
1: Enable
08-11
08-12
Reserved
08-13
Selection of
Over-
Torque
0: Over-Torque
Detection is
Disabled.
0

Other manuals for TECO F510 series

Related product manuals