40
Group 17: IM Motor Automatic Tuning
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
17-00
Mode
Selection of
Automatic
Tuning
0: Rotational
Auto-tuning
VF:2
SLV:6
1: Static Auto-
tuning
2: Stator
Resistance
Measurement
3: Reserved
4: Loop Tuning
5: Rotational
Auto-tuning
Combination
(Item: 4+2+0)
Note
6: Static Auto-
tuning
Combination
(Item: 4+2+1)
Note
17-01
Motor Rated
Output
Power
0.00~600.00 -
17-02
Motor Rated
Current
0.1~1200.0 -
17-03
Motor Rated
Voltage
200V: 50.0~240.0
-
400V:100.0~480.0
-
17-04
Motor Rated
Frequency
4.8~400.0 60.0
17-05
Motor Rated
Speed
0~24000 KVA
*a
17-06
Pole
Number of
Motor
2~16 (Even) 4 *6
17-07 Reserved
17-08
Motor No-
load Voltage
200V: 50~240
KVA
*a
400V: 100~480
17-09
Motor
Excitation
Current
0.01~600.00
(15%~70%
motor rated
current)
KVA
*a
1
17-10
Automatic
Tuning Start
0: Disable
0
1: Enable
17-11
Error
History of
Automatic
Tuning
0: No Error
0
1: Motor Data
Error
2: Stator
Resistance
Tuning Error
3: Leakage
Induction
Tuning Error
4: Rotor
Resistance
Tuning Error
5: Mutual
Induction
Tuning Error
6: Reserved
Group 17: IM Motor Automatic Tuning
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
7: DT Error
8: Motor
Acceleration
Error
9: Warning
17-12
Leakage
Inductance
Ratio
0.1 ~ 15.0 3.4
17-13
Slip
Frequency
0.10 ~ 20.00 1.00
17-14
Rotational
Tuning
Mode
Selection
0: VF Mode
1: Vector Mode
0
Note1
*a: KVA means the default value of this
parameter will be changed by different
capacities of inverter.
1: It can be set when 17-00=1, 2, 6.
Group 18: Slip Compensation
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
18-00
Slip
Compensati
on Gain at
Low Speed
0.00~2.50 0.00
*d
*1
18-01
Slip
Compensati
on Gain at
High Speed
-1.00~1.00 0.0 *1
18-02
Slip
Compensati
on Limit
0~250 200
18-03
Slip
Compensati
on Filter
Time
0.0~10.0 1.0
18-04
Regenerativ
e Slip
Compensati
on Selection
0: Disable
0
1: Enable
18-05
FOC Delay
Time
1~1000 100
18-06 FOC Gain 0.00~2.00 0.1
*d: Default value is 0.00 in V/F mode while it is
1.0 in SLV mode.
Group 19 Reserved

Other manuals for TECO F510 series