42
Group 22: PM Motor Parameters-
only available when PM Control Mode
is selected
Code
Parameter
Name
Setting Range Default
Attribu
te
22-00
Rated
Power of
PM Motor
0.00~600.00 KVA
22-01 Reserved
22-02
Rated
Current of
PM Motor
0.1~999.9 KVA
22-03
Pole
Number of
PM Motor
2~96 6
22-04
Rated
Rotation
Speed of
PM Motor
6~60000
(22-04, 22-06,
only need to set
one of them,
the program will
calculate the
other.)
1500
22-05
Maximum
Rotation
Speed of
PM Motor
6~60000 1500
22-06
PM Motor
Rated
Frequency
4.8~400.0 75.0
22-07
~
22-09
Reserved
22-10
PM SLV
Start
Current
20 ~ 200%
Motor Rated
Current
80
22-11
I/F Mode
Start
Frequency
Switching
Point
1.0 ~ 20.0%
Motor Rated
Current
10.0
Note2
22-12
22-13
Reserved (Note6)
22-14
PM Motor
Armature
Resistance
0.001 ~ 30.000 1.000
22-15
PM Motor
D-axis
Inductance
0.01 ~ 300.00 10.00
22-16
PM Motor
Q-axis
Inductance
0.01 ~ 300.00 10.00
22-17 Reserved
22-18
Flux-
Weakening
Control
0~100 0
Note1
22-19
22-20
Reserved
22-21
SLV PM
Motor
Tuning
0: Disable
0
1: Enable
22-22
Fault
History of
SLV PM
0: No Error
0 *4
1~4:
Reserved
Group 22: PM Motor Parameters-
only available when PM Control Mode
is selected
Code
Parameter
Name
Setting Range Default
Attribu
te
Motor
Tuning
5: Circuit
tuning time
out.
6: Reserved
7: Other motor
tuning errors
8: Reserved
9: Current
Abnormity
Occurs while
Loop
Adjustment.
10: Reserved
11: Stator
Resistance
Measurement
Timeout
12: Reserved
22-23
PM SLV
acceleration
time
0.1~10.0 1.0
Note2
22-25
Detection
Mode
Selection of
Default
Magnetic
Pole
0: Angle before
Stop
3
(Note6)
Note4
1: Mode 1
2: Mode 2
3: Mode 3
22-26
Estimator
Mode
0~1 (in PMSLV
mode)
0
Note6
22-27
Mode 2
Voltage
Command
5~100 (22-
25=2 is
enabled)
50
Note4
22-28
Mode 2
Frequency
Division
Ratio
0~4 (22-25=2 is
enabled)
2
Note4
22-29
Field-
Weakening
Voltage
Control
80~100 95
Note4
22-30
Speed
Estimation
Gain
1~100
85
Note6
22-31
Speed
Estimation
Filter Value
1~2000
60
Note6

Other manuals for TECO F510 series