Page 3 of 9 06/10/17
Remote speed reference and Remote run
1) Ensure that you have carried out installation & wiring requirements as per
previous page before you proceed.
2) For remote potentiometer OR remote 2-10V / 0-10V dc signal use the
following terminals:
Terminal 10V. The supply provided for use with the potentiometer.
Terminal AVI. Potentiometer wiper connection.
Terminal AGND. 0Vdc.
For 0-20mA / 4-20mA signals use the following terminals:
Terminal ACI.
Terminal AGND. 0Vdc.
Remote mode wiring. Speed reference .
1) Connect remote start switch if required according to diagram in the
instruction manual.
Terminals +24V & S1 (Forward run)
Terminals +24V & S2 (Reverse run)
Note: For Frames 3&4
For PNP ( Positive Voltage switching) Using +24VDC
Need a shorting link between Terminals COM & SC
Check/ verify and alter parameters
Check / verify and alter parameters for remote start & remote frequency as
necessary before you proceed. Parameters 00-02 & 00-05
See quick start parameter list & How to alter parameters.