400V Three phase (PNP input)
Frame 2 (0.75 ~2.2KW)
AC Power
source
L1
S2
S3
S4
+
T1
T2
T3
S5
+24V
S1
-
Frequency
reference or PID
Multi-function input
Fuse
Inverter
output
Ground
E
Main
Switch
Power
input
RS485
Pin1 to Pin 8
AO
AGND
+
-
RB
RA
Multi-function output
0~10V
CON2
10V
AVI (0~10V)
ACI (0~20mA)
AGND
AO
Relay output
250VAC/1A
(30VDC/1A)
M
L3
L2
1:Data+
2:Data-
3:Data+
4:Reserved
5:Reserved
6:Data-
7:5V
8:GND
P
BR
P
BR
P, BR for 400 series
400V Frame 2 models.
L510-401-SH3F-P /L510-402-SH1F-P / L510-403-SH1F-P