Challenger Series Installation and Quick Programming Manual 37
6. Press [ENTER] to display the first item for path 3, and then select option
1–Main.
7. Press [ENTER] to step through the options, and change the default settings if
required (in particular, change Enabled to Yes). You might also need to
change the account code and the computer password (default is
0000000000).
8. When returned to the Path menu select option 6Path IP Address.
9. Press [ENTER] to step through the options, and program the following
settings (in particular, program the Titan computer’s IP address).
Use the default values (if applicable) for the Send and Listen IP Port numbers
(default is 3001) and UDP/IP.
10. Press 0 [ENTER] as needed to exit from the Communications menu.
11. In Titan, select Ports from the Admin menu.
12. In the port record select UDP/IP, enter a port number, description, Challenger
panel’s IP address, and IP Port number (for example 3001). Save the record.
13. Connect the Challenger panel’s Ethernet port to the LAN or directly to the
Titan computer via a Cat 5 cable.
14. Select Challenger from the Admin menu.
15. In the Challenger record, ensure the Challenger No. and Security Password
are the same as programmed via RAS, type the port number in the Port field,
and select UDP/IP as the communications mode. Save the record.
16. Select Open/System from the File menu, select Active System, and then save
the record. The connection indicator at the bottom of the Titan window
displays green to indicate a successful connection.
Programming users
Unless you will be programming (adding) the system’s users yourself, you will
need to program at least one administrator who will be able to program additional
users. See Challenger Series Administrators Manual for details.
The default values for User 50, the master code, are:
Name TECOM Master
PIN 4346
Alarm Group 3 (contains all areas, as defined by Area Group 1)
Door Group 1
Floor Group 1