Betriebsanleitung/Operating manual
F2301/F23C1/F23S1
www.tecsis.de BD_BE_912 c 37
Model series
F23C1 Version
ATEX/IECEx Ex ib
1)
F23C1 Version
SIL-3 nach EN 62061:2005
Relative linearity error
2)
Relative reversibility error
Temperature effect on zero signal
Temperature effect on characteristic value
Mechanical characteristics
Permissible oscillation stress
Rated displacement s
nom
mm
< 10 kN: < 0.02
< 100 kN: < 0.2
Material of measuring spring
corrosion resistant stainless steel
ultrasonic tested 3.1 material / (optionally 3.2)
Operating temperature range B
T, G
°C
operating temperature range see
chapter 10.1 on a page 43
-30…80
Storage temperature range
Electrical characteristics
Current consumption mA
Current output 4 … 20 mA
2-wire: signal current
2-wire: signal current,
Current output 4 … 20 mA
3-wire: < 8 mA,
Supply voltage
VDC 10…30 for current output
10 … 30 VDC for current output
14 ... 30 VDC voltage output
Burden
Ohm
≤ (UB–10 V)/0,024 A for current output
> 10 kΩ voltage output
≤ 2 (within 10% bis 90% F
nom
)
4)
Protection (acc. to EN 60529/IEC 529)
Vibration resistance
(acc. to DIN EN 60068-2-6)
20 g, 100 h, 50...150 Hz
Reverse voltage, overvoltage and short-circuit protection
Immunity
acc. DIN EN 61326-1/DIN EN 61326-2-3
(optional EMC ruggedized version)
Electrical connection
Circular connector
M 12x1, 4-pin
Circular connector
M 12x1, 4-pin
Options
Certificates, Strength tests,
3D-CAD data (STEP, IGES) on request
1)
The load pins with ignition protection type “ib” must only be supplied using galvanically-isolated power supplies.
Suitable supply isolators are also optionally available eg. EZE08X030003
2)
Relative linearity error is specified acc. to VDI/VDE/DKD 2638 chapter 3.3.6 b.
3)
Other SIL-shifts are available on request.
4)
Other response times are available on request.