5.2. Electrical connection
WARNING
Explosion hazard!
The conductivity of lines and system parts must be checked in order to prevent static
charges from building up. Leakage resistances < 10^6 Ohm must be ensured.
The Operator must ensure the equipotential bonding of the unit. To do this, use the earthing
point on the back of the unit.
CAUTION
Health hazard arising from unintentional cleaning processes.
Switch on the control only if the unit is in operational condition.
NOTICE
Electric malfunction possible in cause of an incorrect power supply.
Pay attention to the admissible supply voltage. Please observe the specifications on the type
plate.
Connect the mains cable (see chapter 2.1) to the power supply.
5.3. Precoating of the filter cartridges
For a longer service life of the filter cartridges, the new filter cartridges can be pretreated with filter aid.
However, this is not necessary when using nano filter cartridges.
Explosion hazard due to static charging of the filter cartridges. Precoating is only
admissible with slack lime.
Please read and refer to "Precoating new filter cartridges" in the chapter "Maintenance". There
you can also find a description of the operating method of the precoat.