10. Diagnostics and troubleshooting
A list of possible system errors is provided in the table.
Error messages of the control unit are described in the enclosed operating manual of the control
unit.
A recommissioning of the device must only occur if it is ensured that the system is functionally
equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after
consultation with TEKA GmbH, by the personnel authorised by the operator.
Adhere to the instructions in the chapter "Safety instructions" and " Maintenance" when carrying out any
repairs. If in doubt, contact our TEKA service department:
Tel: +49 2541-84841-0
E-mail: info@teka.eu
Plug power supply is missing or
incorrectly inserted.
Plug connector check power
supply / plug in correctly.
Check the mains, remove error if
possible.
Dust at the dust
collecting tank.
There is too much dust in the dust
collection container.
Empty the dust collecting tank.
The clamping lever has not been lift
up.
Lift up the clamping lever.
The seal of the dust collecting tank is
damaged.
The seal must be replaced.
The compressed air for the dedusting
is set too high.
Reduce the compressed air.
Dust at the service door
of the filter housing.
The door is not correctly closed.
The seal between the service door and
filter housing is damaged.
The seal must be replaced.
The compressed air for the dedusting
is set too high.
Reduce the compressed air.
Escape of dust at the hinge.
The hinge must be reoriented or
replaced.
Suction power too low
(smoke hardly
extracted).
Filter element is saturated.
Replace the filter package,
dispose of old filter properly!
Filter elements are saturated because
no compressed air is connected.