2465B/2467B Service
FRONT-PANEL TROUBLESHOOTING
FRONT-PANEL
TROUBLESHOOTING
PRESS
AND
HOLD
AV
AND AT
,
THEN
PRESS SLOPE
TO
ENTER MONITOR
SCROLL
TO
EXERCISER
01 USING
THE
TRIGGER MODE SWITCH
PRESS
UP AND
RELEASE
THE
TRIGGER
COUPLING SWITCH
TO
ENTER ROUTINE
YES
REPAIR FAULTY
MODE SWITCH
YES
PROBABLE CAUSE:
SHORTED DIODE
ON
SUSPECT COLUMN
YES
PROBABLE CAUSE:
1) OPEN DIODE
2)
BAD
SWITCH
PROBABLE
CAUSE:
BAD
SWITCH
PRESS
THE A/B
TRIG SELECT
BUTTON
TO
EXIT
THE MONITOR
MANUALLY
EXERCISE
THE
FRONT-PANEL
SWITCHES
AND
OBSERVE
THE
ASSOCIATED LEDS
YES
MANUALLY EXERCISE
EACH POT
,
OBSERVING
THE CONTROL'S
FUNCTION
PROBABLE CAUSE:
AN INTERMITTENT
POT
OR
SWITCH
IS INTERRUPTING
FRONT-PANEL SCAN
PROBABLE CAUSE:
DEFECTIVE
POT
REPAIR
INDICATED
FAULT
MOVE
A
FRONT-
PANEL SWITCH
IN
ORDER
TO
UPDATE
THE
LED
DATA
MAIN
INSTRUMENT
IS
NOT
PROPERLY
READING
THE
POT'S VALUE
YES
CONTROL BOARD
FAULT
YES
EXTRA LEDS
ARE LIT.
PROBABLE CAUSE:
DEFECTIVE SHIFT
REGISTER
PROBABLE CAUSE:
DEFECTIVE SHIFT
REGISTER
PROBABLE
CAUSE:
DEFECTIVE
LED(S)
MANUALLY EXERCISE
EACH SWITCH,
OBSERVING
THE
CONTROL'S FUNCTION
YES
MAIN INSTRUMENT
IS
NOT
PROPERLY
READING
THE
POT'S VALUE
PROBABLE CAUSE:
AN INTERMITTENT
POT
OR
SWITCH
IS INTERRUPTING
FRONT-PANEL SCAN
PROBABLE CAUSE
DEFECTIVE
POT
YES
REPAIR CONTROL
CIRCUITS
IN THE
MAIN INSTRUMENT
REPAIR CONTROL
BOARD AND/OR
READOUT BOARD
6019-29A
-l 3
3D
3D
oo
S3
"I
©

Table of Contents