CALIBRATION
TEST EQUIPMENT
REPLACEMENT
Calibration
Test
Equipment
Chart
This chart
compares TM
500
product performance
to
that of
older
Tektronix
equipment. Only
those
characteristics where significant
specification differences occur,
are listed.
In some
cases the new
instrument
may
not
be
a
total
functional
replacement. Additional
support instrumentation
may
be needed or
a
change
in
calibration
procedure may
be necessary.
Comparison
of
Main
Characteristics
DM 501 replaces 7D13
PG
501 replaces 107 PG 501
-
Risetime
less
than 107
-
Risetime less than
3.5 ns
into
50
Q. 3.0
ns into 50 O.
108 PG 501
-
5
V
output
pulse; 108
-
10
V output pulse
3.5 ns
Risetime
1
ns
Risetlme
PG
502
replaces
107
108
PG 502
-
5
V
output
108
-
10
V
output
111
PG 502
-
Risetime less than 111
-
Risetlme 0.5
ns; 30
1 ns; 10 ns to 250 ns
Pretrigger pulse
Pretrigger
pulse
delay
delay
PG
508
replaces 114
Performance of replacement
equipment
is
the
same
or
115 better than equipment being
replaced.
2101
PG 506
replaces 106 PG
506
-
Positive-going
106
-
Positive
and Negative-
trigger
output sig-
going
trigger
output
nal at least 1 V;
signal,
50
ns and 1
V;
High
Amplitude
out-
High Amplitude output,
put,
60
V.
100 V.
067-0502-01
PG 506
-
Does
not
have
0502-01
-
Comparator
output
chopped
feature.
can
be alternately
chopped
to
a refer-
ence
voltage.
SG
503 replaces
190,
190A, 190B
SG 503
-
Amplitude
range
190B
-
Amplitude
range 40 mV
5
mV
to
5.5
V
p-p.
to 10 V
p-p.
191
067-0532-01
SG
503
-
Frequency
range 0532-01
-
Frequency
range
250
kHz
to 250 MHz. 65 MHz
to
500 MHz.
SG
504 replaces
067-0532-01
SG 504
-
Frequency range 0532-01
-
Frequency
range
245
MHz
to
1050 MHz.
65
MHz
to 500 MHz.
067-0650-00
TG 501 replaces
180,
180A
TG
501
-
Trigger
output-
180A
-
Trigger
pulses
1,
10,
slaved
to
marker
100 Hz;
1.
10,
and
output from
5 sec
100 kHz. Multiple
through 100
ns. One time-marks can be
time-mark can
be
generated simultan-
generated at
a time.
eously.
181
181
-
Multiple
time-marks
184
TG
501
-
Trigger
output-
184
-
Separate
trigger
slaved
to market
pulses of
1
and 0.1
output from
5
sec
sec;
10,
1,
and 0.1
through 100
ns. One
ms; 10 and
1
/us.
time-mark can be
generated
at a time.
2901
TG 501
-
Trigger output- 2901
-
Separate trigger
slaved to marker pulses, from
5 sec
output from 5 sec to
0.1
fis.
Multiple
through
100 ns. time-marks can be
One time-mark can generated simultan-
be
generated at
eously.
a time.
NOTE: Ail TM
500
generator
outputs are
short-proof. All
TM
500
plug-in
instruments
require TM
500-Series
Power
Module.
REV
B.
JUN
1978