Error messages
Number Text Possible causes
Operation wher
eit
may occur
1 FileNameErro
r: File doesn’t e xist:
<lename>
The selected .vmset le does not
exist. (You need to specify the full
path if the le
is not in the folder
C:\VMApps\)
Recalling set
tings.
2
Cannot write le: le already exists:
<lename>
You need to rename <lename> so
that the le can be w ritten.
Saving settings;
Generating a report.
3
File Name Error. Invalid character(s)
in le name
Invalid characters in the lename.
Invalid char
acters are: “|”, “:”, “/”, “,”,
“<”, >”, “*”, “\”, and “?”.
Saving settings;
Generating a
report.
4
No Measurement Selected
No measurem
ents selected in the
Conguration > Measurements menu.
Executing a
measurement;
Generating a report.
5
Cannot create Report. Not all selected
measures ha
ve been Run
Need to run a measurement and wait
until it completes before generating
a report.
Generating a report.
6 Invalid Filename
The le doe
sn’t exist or the path is
incorrect. You need to specify the
full path if the le is not in the folder
C:\VMApps
.
RecallSet
tings;
SaveSettings;
ReportGenerate (only
when calle
dviaGPIB).
7
Invalid Argument
Inappropr
iate argument used for the
particular GPIB c ommand.
All GPIB co
mmands.
8
Command Overow GPIB commands were sent too
rapidly. Increase the delay time
between c
ommands to prevent this
problem (100 milliseconds interval
recommended), or use handshaking
with OPC
omplete.
When GPIB commands
are sent too rapidly.
9
Command
Missed
This error indicates that a command
sent in t
he last second may not have
been processed, so you should return
to a recent (known) conguration and
resend
the m ost recent commands.
Sending
aGPIB
command.
10
Error o
ccurredinconguring MIU
Improper serial connection to MIU
or one o
f the CH1/CH2/CH3/CH4
connector c ables are disconnected
from the VM Series system.
Running any
measur
ement using
the MIU.
VM Series Video Measurement System Quick Start User Manual 47

Other manuals for Tektronix VM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix VM Series and is the answer not in the manual?

Tektronix VM Series Specifications

General IconGeneral
BrandTektronix
ModelVM Series
CategoryTest Equipment
LanguageEnglish

Related product manuals