Incoming Inspection
6. Using the audio
breakout cable or equivalent, connect the analog audio
generator to the rst Line A input pair and verify that the output level of the
generator signal is 18 dBu, as indicated on the audio bars.
7. Repeat step 6 for the second and third line A input pair.
8. Record Pass or Fail in the test record.
9. Press and hold the Display Select button 4 button to display the AUDIO
pop-up menu.
10. Select Analog Input and then s elect Analog B.
11. Press the AUDIO button brieytodismissthemenu.
12. Repeat step 6 for all three Line B input pairs.
13. Record Pass or Fail in the test record.
Analog Audio O utput
(Options AD and DDE)
1. Restore the Factory Preset. (See page 60, Restore the Factory Presets.)
2. Press and hold the Display Select button 4 button to display the AUDIO
pop-up menu.
3. Select Analog Input and then select Analog A.
4. Press the AUDIO button brieytodismissthemenu.
5. Using the audio breakout cable or equivalent, connect the rst Line A input
pair to the analog audio generator and verify that the output level of the
generator is 18 dBu, as indicated on the audio bars.
6. Press CONFIG to display the CONFIG menu.
7. Select Audio Inputs/Outputs > Atten Analog Out.
8. Press SEL andusetheGENERALknobtoadjustthevalueto0db,thenpress
SEL again to set the value.
9. While still in the Audio Inputs/Outputs submenu, select Analog A > Analog
Output Map.
10. Press SEL to display the Analog Output to Analog “A” Bar Map.
11. Put an X in the rst bar pair row for Analog Outputs 1&2, 3&4, 5&6, and 7&8.
12. Press CONFIG to exit the CONFIG menu.
13. Connect the rst a
nalog output pair on the breakout cable to the second line
A input pair.
14. Verify on the level meter bars that the second set of bars is within 1 dB of the
rst set of bars.
15. Connect the second analog output pair on the breakout cable to the second
line A input pair.
68 Waveform Monitors Specications and Performance Verication

Table of Contents

Other manuals for Tektronix WFM6120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix WFM6120 and is the answer not in the manual?

Tektronix WFM6120 Specifications

General IconGeneral
BrandTektronix
ModelWFM6120
CategoryMonitor
LanguageEnglish

Related product manuals