71www.behnke-online.de
GB
Instructions SIP intercoms series 20-0001BS, 20-0014BS, 20-0016BS
Commissioning and configuration
▸
Announce IP address: Press twice
▸
Start/exit the network configuration mode:
Press 3 times.
If access to the SIP station in the network is no
longer possible, an attempt is made to obtain
an IP address via DHCP by starting this function.
If this is not possible, an IP address is assigned
in the Link Local area. Remember that if the
device has assigned itself an IP address, you
also need to assign its computer an IP address
on the Link Local Network 169.254.0.0/16 so
that you can access the device. In addition,
the device and the computer must be on the
same network segment for a connection to be
possible.
Furthermore, the SIP intercom station sets up a
WiFi network for 10 minutes and thus enables
configuration via this WiFi (SIP intercom station
cannot be used as WiFi intercom station,
only temporarily possible for configuration
purposes).
For more information on configuration via WiFi,
press the configuration key 4 times
Explanation of how to access the SIP intercom
via WiFi: Press 4 times.
WiFi name: behnke-station
WiFi password: behnke-station
Access via browser: http://behnke-station
The web frontend is accessed as described in
point 4.
If the device does not start as described here,
refer to the section "System startup problems".
4.2. System startup problems
In the event of an error, the device may not
start, as described in the section "Startup
procedure".
Problem after firmware update
If the device does not start properly after a
firmware update, then it can be switched back
to the previously used firmware version as
described below.
Disconnect the device from the power
supply (network cable / PoE injector)
Wait briefly and then reconnect the
power supply
Immediately press the configuration
key and hold before status LED lights
up
Status LED lights up red
Immediately release the configuration
key and then press 2 times briefly
Status LED lights up yellow
Device starts, activates the firmware
on the inactive slot and then restarts